美国布鲁克海文仪器公司上海代表处
访问手机展位
微信小程序展位
留言咨询
(我们会第一时间联系您)
关闭
留言类型:
     
*姓名:
*电话:
*单位:
Email:
*留言内容:
(请留下您的联系方式,以便工作人员及时与您联系!)
认证信息
金牌会员 第 6
名 称:美国布鲁克海文仪器公司上海代表处
认 证:工商信息已核实
访问量:526388
手机网站
扫一扫,手机访问更轻松
公司品牌
品牌传达企业理念
公司动态
Nanobrook Omni测量应用案例-47

美国布鲁克海文仪器公司上海代表处  2018-11-29  点击958次

文献名: Lowering Fresh Water Usage in Hydraulic Fracturing by Stabilizing scCO2 Foam with Polyelectrolyte Complex Nanoparticles Prepared in High Salinity Produced Water

 

作者:      H. Hosseini (University of Kansas) | J. Tsau (University of Kansas) | E. Peltier (University of Kansas) | R. Barati (University of Kansas)

 

 

摘要:Polyelectrolyte complex nanoparticle (PECNP) systems compatible with produced water were developed to improve supercritical CO2 (scCO2) foam stability and to reduce fluid loss for fracturing applications. Foam viscosity, stability, fluid loss properties and cleanup of injected liquid through the formation were enhanced by PECNP-surfactant systems prepared in produced water medium. Taking advantage of produced water as energized fluids for fracturing requires enhanced compatibility of gas/liquid mixture. Two produced water recipes of 33,333 and 66,666ppm TDS were used to prepare 1 w/w% surfactant solutions. PECNP was formed as a mixture of positively- and negatively- charged polyelectrolytes. Experimental setup was designed to determine the aqueous foam stability at actual reservoir conditions. Rheological measurement was performed to measure the stability of the bulk foam under shear and to evaluate the foam texture properties. The improved viscosity of different proportions of PECNP-Surfactant (9:1, 8:2, 7:3, and 6:4) in aqueous foam mixtures was observed as compared to surfactant stabilized CO2 foam. The flow consistency index observed in the shear thinning region was also increased from 1184.3 to 2916.4 Pa sn in 33,333ppm and from 1035.7 to 1683.1 Pa snin 66,666ppm brine solutions. The view cell results revealed the high stability and longevity of scCO2 foam employing various proportions of surfactant to nanoparticle as oppose to surfactant generated foam in which the foam height shortened faster. The presented scCO2 generated foam can preserve the foam cellular structure in absence of crude oil. The PECNP-Surfactant system successfully lowered the interfacial tension to up to 74% and 93% for 33,333 and 66,666ppm brine salinity, respectively. Fluid loss was measured to evaluate fluid leak-off from a core when the high flow velocity along the core exists. The fluid loss for both CO2 and water leak-off were also lowered employing PECNP- Surfactant containing foam.

                                                 


联系电话
关闭
虚拟号将在180秒后失效,请在有效期内拨打
为了保证隐私安全,平台已启用虚拟电话,请放心拨打.(暂不支持短信)
使用微信扫码拨号
是否已沟通完成
您还可以选择留下联系电话,等待商家与您联系
*需求描述:
*单位名称:
*联系人:
*联系电话:
Email:
(请留下您的联系方式,以便工作人员及时与您联系!)